| Installation |
| A full 1-1/8" edge surface allows for quick installation with virtually no risk
of splitting. Installation of RIMBOARDs requires 8d common or ring-shank
nails.* |
| |
-
I-Joist - drive 1 nail into the top flange and 1 into the bottom flange
-
Plate - toe-nail RIMBOARD at 6" on centre to wall plates
-
Floor Deck - space fasteners at 6" on centre
-
Ledger - use 1/2 " lag screws and ensure they completely penetrate RIMBOARD.
Please refer to building code requirements for number and placement of lag
screws.
-
Starter Joist - when RIMBOARDs are used as starter joists to maintain the
vertical loading, there are several installation options, such as blocking
(maximum 24" o.c.), double up the RIMBOARDs, or place an I-JOIST adjacent to
the RIMBOARD. Please consult your designer for the appropriate option and
details for your application
RIMBOARD is designed to span openings of 4' or less.
|
| * A larger nail size may be required by some I-JOIST manufacturers. |
|


RIMBOARD from Norbord is a certified "Green Approved Product" for the National Green Building Standard
|
|
|